Homelab & Self-hosting9 min read

Monitoring ZFS, SMART and UPS in a Homelab

A degraded pool, a dying disk and a UPS on battery all look fine on a CPU graph. Here's how to catch them before they cost you data.

The Ensju team
On this page

Most homelab data loss doesn't start with a crash. It starts weeks earlier, quietly: a pool that went DEGRADED and kept serving files, a drive that began reallocating sectors, a UPS that has been running on battery since the storm. None of it shows up on a CPU or disk-usage graph, and all of it is cheap to watch once you know which numbers matter.

The short version

  • ZFS: alert on any pool state other than ONLINE, on rising error counters, and on scrubs that stop completing.
  • SMART: watch reallocated, pending and uncorrectable sectors on HDDs, and endurance and media errors on NVMe. Rising counts matter more than totals.
  • UPS: alert on battery, low battery, and on the UPS going unreachable, because that's when shutdown scripts fail.
  • Keep raw-disk access out of anything network-facing: read SMART with a root helper, not a privileged agent.
  • A failing-disk alert should never clear on its own. Dismiss it when the drive is replaced.

Why usage graphs aren't enough

CPU, memory and disk usage tell you how busy a machine is today. They say nothing about whether its storage is about to fail. ZFS will keep serving data from a degraded mirror, a drive with a growing list of bad sectors still reads fine most of the time, and a server on UPS battery looks exactly like a server on mains power, right up until the battery runs out. The failures that cost you data are the ones that look healthy from the outside.

What to watch on a ZFS pool

Pool health

A healthy pool reports ONLINE. Anything else (DEGRADED, FAULTED, UNAVAIL, and so on) means a device is missing or failing, and your redundancy is already spent. This is the alert that matters most, because the next failure in a degraded vdev is the one that loses data. Check it by hand with:

Prints only pools with problems
zpool status -x

Error counters

zpool status shows read, write and checksum error counts per device. A pool can stay ONLINE while these climb: ZFS repairs what it can from redundancy and carries on. A counter that goes up is worth an alert even when the pool looks fine, because it's often the first sign of a failing drive, a bad cable or a flaky controller.

Scrubs

A scrub reads every block and checks it against its checksum, which is how ZFS finds silent corruption before you need the data. Monthly is a common rhythm for a home pool. Many Debian-based systems, Proxmox included, ship a scheduled scrub with the ZFS packages, but don't assume it's running: alert when no scrub has completed in your chosen window.

What to watch with SMART

SMART is the drive's own health report. You can read it with smartctl -a /dev/sda (from smartmontools). Most of what it prints is noise; a handful of numbers are worth alerting on.

Drive typeWatchWhy
HDDReallocated sector countSectors the drive has already given up on
HDDCurrent pending sector countSectors it couldn't read and may give up on
HDDOffline uncorrectableSectors that failed even on retry
NVMePercentage usedHow much of the rated write endurance is spent
NVMeMedia errorsData integrity errors the controller couldn't correct
AnyOverall verdictPASSED or FAILED: the drive's own last word

The trend is what matters. A drive that has had 8 reallocated sectors for three years is a different story from one that went from 0 to 8 this week. And don't wait for the overall verdict: by the time a drive reports FAILED, it has usually been telling you for a while.

SMART is an early warning, not a guarantee

Plenty of drives die without a single warning sign. SMART monitoring buys you time on the ones that do warn you. It doesn't replace redundancy or backups.

What to watch on a UPS

Network UPS Tools (NUT) talks to most UPS models and reports their status with short codes: OL (on line power), OB (on battery) and LB (low battery). Check yours with:

Ask NUT for the UPS's current state
upsc myups@localhost
  • On battery tells you the power is out, often before anything else does. Allow a short grace period so a brief flicker doesn't page you.
  • Low battery means shutdown is minutes away. It should alert at once, with no grace period.
  • Unreachable is the sneaky one: if the monitoring host can't talk to the UPS, your automatic shutdown can't either.

Setting it up with Ensju

Ensju's server agent (0.6.0 and newer) has three optional collectors, one each for ZFS, SMART and UPS. All three are off by default, because each reads something the agent has no business touching unless you asked. Tick them in the Reinstall / Update Agent dialog on a server's page, or add them to the install command:

Linux install with all three collectors
curl -sSL https://ensju.com/agent/install.sh | sudo ENSJU_TOKEN=ensrv_xxxxxxxx \
  ENSJU_ZFS=true ENSJU_SMART=true ENSJU_UPS=true sh
  • ZFS needs zpool on the path, and no extra privilege.
  • SMART needs smartmontools 7.0 or newer. The installer sets up a separate root-owned helper on a timer that runs smartctl and writes a report file; the agent itself stays unprivileged and only reads that file. A smartctl that hangs on a dying drive delays the helper, never your server's check-in.
  • UPS needs a running NUT server with upsc on the path. To read a UPS attached to another machine, add ENSJU_UPS_SERVER=host.

The collectors run on Linux and FreeBSD, which covers Proxmox, plain Debian or Ubuntu hosts, and OPNsense or pfSense boxes. Re-running the installer keeps your existing settings, so adding a collector later is just running the command again with the new flag.

What alerts, and when

ConditionFires whenClears when
Pool degradedPool state isn't ONLINEThe pool is ONLINE again
Pool errorsA read, write or checksum counter goes upNo new errors for 24 hours
Scrub overdueNo completed scrub in 45 days (adjustable)A scrub completes
Disk failingFAILED verdict, a rising sector count, NVMe endurance at 90%, or a media errorNever on its own: dismiss it
UPS on battery2 check-ins on battery (adjustable), or at once if also lowBack on line power
UPS low batteryThe UPS reports LBIt stops reporting it
UPS unreachableThree failed reads in a rowA clean read

Two of these are deliberate. A failing-disk alert never clears by itself, because a drive that started reallocating sectors isn't healthy again just because this hour's numbers held steady; it stays open until you dismiss it or pull the drive. And the scrub clock starts when Ensju first sees a pool, so switching ZFS monitoring on for an old server doesn't page you tomorrow about a scrub schedule you never had.

Alerts go to the same channels as the server's offline alerts. All of this is on every plan: Free covers 1 server agent, and Homelab ($10/mo) covers 5.

The rest of the storage picture

Healthy disks still fill up, and healthy pools still lose data when the backup job quietly stopped running in March. Two more checks finish the picture:

  • A disk-full forecast that alerts on "fills in 6 days" instead of a percentage, so a slow leak gets caught early and a big, stable disk doesn't nag you.
  • A heartbeat on every backup job, so a backup that silently stops running pages you.

If you're setting up a lab from scratch, the homelab monitoring guide covers the rest of what's worth watching.

Frequently asked questions

How often should I scrub a ZFS pool?
Monthly is a common rhythm for a home pool on consumer drives. What matters more is that scrubs actually run and finish: a scrub schedule that silently stopped months ago is worse than no schedule, because you think you're covered. Alert when no scrub has completed in your chosen window.
Which SMART attributes actually predict a failing drive?
On spinning disks, watch reallocated sectors, pending sectors and offline uncorrectable sectors. A count that is rising matters more than its absolute value. On NVMe drives, watch the endurance used percentage and media errors. The overall SMART verdict (PASSED or FAILED) is the last line of defense, not the first.
Does SMART monitoring need root access?
Reading SMART data needs raw device access, which normally means root. Ensju keeps that out of the monitoring agent: a separate root-owned helper runs smartctl on a timer and writes a report file, and the unprivileged agent only reads the file.
Can I monitor a UPS that's plugged into a different machine?
Yes, if that machine runs a NUT server. Point the agent at it with ENSJU_UPS_SERVER=host (or host:port) and it queries that NUT server instead of a local one.
Does this work on OPNsense or pfSense?
Yes. The ZFS, SMART and UPS collectors run on Linux and FreeBSD, and OPNsense and pfSense are FreeBSD-based. They are ignored on macOS and Windows.

Get the next one in your inbox

Practical, vendor-neutral monitoring tips — what to watch and how to alert on it — plus the occasional Ensju update. No spam, unsubscribe anytime.